Capacitance tolerance (at 1KHZ): ±5%(J), ±10%(K), +10-5 %(U), Other tolerance upon request
Operating temperature range: Min. temperatures:-40℃, -25℃ Max. temperatures:+85℃, +105℃
Withstand voltage (at 25±5℃): a)Between terminals:1.5×RV for 60Sec. No flashover or permanent breakdown shall occur, but self-healing are allowed. b)Between terminals and case: 2RV+1KV(2000V Min.) for 2Sec. During this test, no dielectric breakdown or flashover shall occur.
Insulation Resistance (Rins): Measured between terminals at 25±5℃, after 1 minute of electrification at 100VDC τ≧30,000s (time constantτ=Cr×Rins)
Dissipation Factor (DF): tanδ, measured at 25±5℃, 10KHZ ≦0.02%
Endurance Test: Test conditions Test step 1:1.4RV for 250h @Test temperature Test step 2:1.4peak current for 1,000 times @ Room temperature Test step 3:1.4RV for 250h @Test temperature Performance During this test, no permanent breakdown, interruption or flashover shall occur. Capacitance change(△C/C):≦±3%